1 Overview

LandStar B series is a PWM common positive solar charge controller that adopts the most

advanced digital technique. The multiple load control modes enable it can be widely used

on solar home system, traffic signal, solar street light, solar garden lamp, etc. The features

are listed below:

 Adopt high quality components of ST,IR and Infineon, make sure product lifespan

 Terminals have UL and VDE certification, the product is more safer and more reliable

 100% input and output in the environment temperature range

 3-Stage intelligent PWM charging:Bulk, Boost/Equalize, Float

 Support 3 charging options: Sealed, Gel, Flooded and User

 RS485 communication interface and Modbus communication protocol

Battery temperature compensation function

 Energy statistics function

 Multiple load control modes

 Extensive Electronic protection

2 Product Features

Remote Temperature(RTS)Port

PV Terminals

Battery Terminals

Load Terminals

RS485 communication Port

★If the temperature sensor is short-circuited or damaged, the controller will charge

or discharge at the default temperature setting of 25 º C.

Figure 2 Connection diagram

Installation Procedure:

Connect the system in the order of ❶battery

accordance with Figure 2"Connection diagram" and disconnect the system in the reverse

BEIJING EPSOLAR TECHNOLOGY CO., LTD.

——Solar Charge Controller

Figure 1 Characteristic

Mounting Hole

Load status indicator

Battery status indicator

Charge status indicator

Tel:+86-10-82894112 / 82894962

NOTE: The LS-B series is a positive ground controller. Any positive

connection of solar, load or battery can be earth grounded as required.

NOTE:While wiring the controller do not close the circuit breaker or fuse

and make sure that the leads of "+" and "-" poles are connected correctly.

NOTE: A fuse which current is 1.25 to 2 times the rated current of the

controller must be installed on the battery side with a distance from the

battery not greater than 150 mm.

NOTE: If an inverter is to be connected to the system, connect the inverter

directly to the battery, not to the load side of the controller.

4 Indicator and button

(1)Indicator

Charge, Load and Battery(orange)indicator flashing

Charge, Load and Battery(red)indicator flashing

①The load is turned ON/OFF via the button when the working mode is Manual Control.

②Clear the faults for the load overload and short circuit .

❶ USB to RS485 converter cable: CC- RS485-RS485-150U

PC software website: www.epever.com(PC Software for the Solar Charge Controller)

❷ USB to RS485 converter cable: CC- RS485-RS485-150U

OTG cable: OTG-12CM

Phone APP software website (support Andriod system only)

www.epever.com(Andriod APP for the Solar Charge Controller)

❸ USB to RS485 converter cable:CC-RS485-RS485-200U-MT)

(1)Battery types

Battery Voltage Control Parameters

Below parameters are in 12V system at 25 º C, please double the values in 24V system

Battery type

Over Voltage Disconnect Voltage

Charging Limit Voltage

Over Voltage Reconnect Voltage

Equalize Charging Voltage

Boost Charging Voltage

Float Charging Voltage

Boost Reconnect Charging Voltage

Low Voltage Reconnect Voltage

Under Voltage Warning Reconnect

Under Voltage Warning Voltage

Low Voltage Disconnect Voltage

Discharging Limit Voltage

Equalize Duration

Boost Duration

1) When the battery type is sealed, gel, flooded, the adjusting range of equalize duration is

0 to180min and boost duration is 10 to180min.

2) The following rules must be observed when modifying the parameters value in user

Website:www.epsolarpv.com/www.epever.com

Information

PV connection normal ,but

low voltage(low irradiance)

from PV, no charging

No PV voltage(night time)

or PV connection problem

Slowly Flashing(1Hz)

In charging

Fast Flashing(4Hz)

PV Over voltage

Slowly Flashing(1Hz)

Fast Flashing(4Hz)

Over voltage

Under voltage

Over discharged

Slowly Flashing(1Hz)

Battery Overheating

Slowly Flashing(1Hz)

Load overload

Fast Flashing(4Hz)

Load short circuit

Controller Overheating

System voltage error

120 min 10~180 min

Related Manuals for Epever LS1024B

Solar charge controller (2 pages)

Solar charge controller (2 pages)

Solar charge controller (20 pages)

Solar charge controller with usb output (2 pages)

Solar charge controller (5 pages)

Solar charge controller (2 pages)

Solar charge controller with built in led driver (2 pages)

Solar charge controller with built in led driver of step-down voltage (2 pages)

Solar charge controller with built-in led driver (2 pages)

Pwm solar charge controller with built in led driver (2 pages)

Solar charge controller with built in led driver (2 pages)

Solar charge controller with built-in led driver (2 pages)

Solar charge controller with built-in led driver (2 pages)

Tracer-an series mppt solar charge controller (44 pages)

Modular mppt solar charge controller (60 pages)

Mppt solar charge controller (60 pages)

Summary of Contents for Epever LS1024B